Monoblocks MTT2.0 4V are complete refrigerating systems plug-in for refrigerated counters. Their easy installation, the manufacturing and quality standards ensure to the customers an innovative, technologically advanced product, owing to cost reduction and time saving.
TECHNICAL DETAILS:
- Application range
- HBP (+2°C; +8°C)
- MBP (-2°C; +6°C)
- LBP (-15°C; -20°C)
- Natural, electrical or hot gas defrost
- High efficiency hermetic compressor
- PP base plate
- PUE insulated evaporator case with high insulation
- Water tray equipped with forced evaporation coil made of anticorrosion stainless steel
- Capillary expansion
- Working up to +40°C external temperature
- Left or right mounting
- Range "plus" (+) for pastry application
- Wiring standard for all models
- Top or back ventilation
ADVANTAGES:
- Easy and fast to install
- Minimized work and cutting on counter
- Reduced after-sales costs
- The integrated evaporator allows more available space in the counter
- Base plate and hole measures for ventilation, standard for all models
- Automatic evaporating system
- Tree NTC probes included
- Possibility of disassembly and reassembly using only the front opening of the table
OPTIONAL:
- Special power supply and voltage
- Wiring kit for the connection to the counter's thermostat
- EC motor fan
- Vertical rail mounting kit
- Evaporator air convoyer
HBP
Code | Modell | Power supply | Compressor | Temperature | Refrigerant | Defrost | Mounting | Ventilation | Weight | Dimensions | |||||||
V | Hz | HP | W | W IN | A IN | Internal | Esternal | Type | Type | Type | Type | Kg | L | P | H | ||
197155 | MTT 2.0 HZ/4V N DX TOP | 220/240 | 50 | 1/3E | 330 | 214 | 1,47 | +2 /+8 | + 40 | R134a | naturale | Rh | Top | 19 | 485 | 290 | 580 |
197165 | MTT 2.0 HZ/4V N SX TOP | 220/240 | 50 | 1/3E | 330 | 214 | 1,47 | +2 /+8 | + 40 | R134a | naturale | Lh | Top | 19 | 485 | 290 | 580 |
197175 | MTT 2.0 HZ/4V N DX BACK | 220/240 | 50 | 1/3E | 330 | 214 | 1,47 | +2 /+8 | + 40 | R134a | naturale | Rh | Back | 19 | 485 | 290 | 580 |
197185 | MTT 2.0 HZ/4V N SX BACK | 220/240 | 50 | 1/3E | 330 | 214 | 1,47 | +2 /+8 | + 40 | R134a | naturale | Lh | Back | 19 | 485 | 290 | 580 |
197153 | MTT 2.0 HU/4V N DX TOP | 220/240 | 50 | 1/3E | 363 | 226 | 1,39 | +2 /+8 | + 40 | R290 | naturale | Rh | Top | 19 | 485 | 290 | 580 |
197163 | MTT 2.0 HU/4V N SX TOP | 220/240 | 50 | 1/3E | 363 | 226 | 1,39 | +2 /+8 | + 40 | R290 | naturale | Lh | Top | 19 | 485 | 290 | 580 |
197173 | MTT 2.0 HU/4V N DX BACK | 220/240 | 50 | 1/3E | 363 | 226 | 1,39 | +2 /+8 | + 40 | R290 | naturale | Rh | Back | 19 | 485 | 290 | 580 |
197183 | MTT 2.0 HU/4V N SX BACK | 220/240 | 50 | 1/3E | 363 | 226 | 1,39 | +2 /+8 | + 40 | R290 | naturale | Lh | Back | 19 | 485 | 290 | 580 |
Test conditions: External temperature +32°C / Evaporating temperature -10°C / Condensing temperature +55°C